| Features |
|
 |
- APPLICATION
ORIENTED
Test Source for Airline Maintenance and American Line Powered
Equipment.
- ADVANCED
TECHNOLOGY
Microprocessor based Digital PWM Design Now Provides Distortion
/ Sinewave.
- SMALL
FOOTPRINT
Compact, Light Weight and Rugged Construction.
- MAXIMUM
STR
As High as 200% for a Cycle.
- HIGH POWER
DESIGN
Various Ratings to Select for Individual Needs.
- TOTAL
POWER
At Ambient as High as 45ºC.
- ENGINEERED
RELIABILITY
Effective Scientific Cooling with Proven Design.
|
|
Crotech
FC-SERIES is a frequency converter range ideally suited for testing
of various Line powered equipment, having input frequency demand
other than mains frequency, e.g. 400Hz for Airline maintenance,
60Hz for U.S and 50Hz for other equipment. The FC-Series has been
designed for total flexibility as regards Input/ Output configurations,
at the same time it covers very wide Power ratings. FC-Series
conceptualizes digital state of the art IGBT based technology
to provide precise low distortion Sine Wave output at very high
efficiency The FC-Series is packaged in compact, lightweight,
and rugged enclosure with effective scientific cooling technique. |
| Technical
Specifications |
| INPUT |
|
| Voltage |
230V AC / 415V
AC, ±15%, 1 or 3Ph, 2/3/4 Wire, 50/60Hz. |
| OUTPUT |
|
| Power |
1KVA (800W)
to 200KVA (160KW). |
| Frequency |
50Hz / 60Hz
/ 83.33Hz / 400Hz / 1000Hz. |
| Voltage |
a) 200V ph-ph
/ 400V ph-ph.
b) Phase 3ph 4W / 3Ph 3W. |
| Regulation |
±1%. |
| ENCL. PROTECTION |
IP-20. |
| COOLING |
Forced Air
Cooling. |
| METERING |
Analogue meters
for AC Voltage & AC Current, Digital Meter for Output frequency.
Optional Digital meters. |
| PROTECTIONS |
Input
Over/Under Voltage, Output Over/under voltage, Phase Fail/Reversal
(for 3 phase inputs), DC Over/under voltage, Output Overload/Shortcircuit,
Overheat, Snubber Circuits for Power Semi-Conductor Devices and
Soft-start feature. |
| INDICATIONS |
Mains On, DC On, Output On, Phase Fail (for 3 phase inputs) Mains
Over/Under Voltage, Output Over/Under Voltage, Output over load
and Overheat. |
| OPTIONAL |
|
| Frequency |
a) Variable
frequency upto ±20% for any of the above center frequencies.
b) 45-65Hz. |
| Voltage |
Any other output
Voltage (Fixed or Variable with ±25%). |
| Enclosure |
IP-21, IP-30,
IP-31 or IP-40. |
| INPUT
230V AC ±15%, 1Ph, 2Wire |
| 1KVA |
2KVA |
3KVA |
5KVA |
7.5KVA |
| FC1P3-1 |
FC1P3-2 |
FC1P3-3 |
FC1P3-5 |
FC1P3-7.5 |
| INPUT
415V AC ±15%, 3Ph, 3/4Wire |
| 20KVA |
30KVA |
50KVA |
100KVA |
150KVA |
200KVA |
| FC3P3-20 |
FC3P3-30 |
FC3P3-50 |
FC3P3-100 |
FC3P3-150 |
FC3P3-200 |
|
|