| Features |
|
 |
- Test Source
for American Line Powered equipment or for Airlines Maintenance
Work Shops
- 115V, 60Hz
or 115V, 400Hz Output Power
- Upto 7.5KVA
Capacity
- High Efficiency
- 85% Approx.
- Sinewave
Output with Less Than 3% Distortion
- Delivers
upto 200% Overload for a Cycle
- Delivers
Full Power in 45°C Ambient Environment
- IGBT based
PWM Technology
- Compact,
Light Weight Construction
|
|
With
increasing Global trade, manufacturers in India need to test equipment
on commercial line supply available in those countries. Equipment
exported to several countries require 115V supply at 60Hz. Equipment
used by aircraft industry needs 115V supply at 400Hz. Crotech
is the largest manufacturer and exporter of Frequency Converters
upto 100KVA capacity in single phase & 200KVA in 3 phase catagory. |
|
An
Crotech Frequency Changer consists of a Rectifier and a Static
Inverter. The Rectifier converts the commercial AC power to very
precise DC power and supplies the Static Inverter. The IGBT-based
Pulse Width Modulation (PWM) technology is used to convert DC
power to a very precise low distortion Sine-wave output at very
high efficiency. |
|
| Technical
Specifications |
| MODEL |
|
FC98-2 |
FC98-3 |
FC98-5 |
FC98-7.5 |
| Rated
Power |
|
2.0KVA
1.6KW |
3.0KVA
2.4KW |
5.0KVA
4.0KW |
7.5KVA
6.0KW |
| Input |
Voltage |
195
Volts to 265 Volts, Single Phase. |
| Frequency |
50Hz
± 3Hz. |
| AC-AC Efficiency |
80%
(approx.) |
85%
(approx.) |
| Output |
Voltage |
115
Volts AC, Single Phase. |
| Regulation |
±1%
(typical). |
| Current |
17.4
Amps |
26.0
Amps |
43.5
Amps |
65.2
Amps |
| Frequency |
60Hz
for FC98-x/60 and 400Hz for FC98-x/400. |
| Frequency Stability |
±0.5%. |
| Waveform |
Sinewave. |
| Distortion |
<3%
on Linear loads. |
| Transient Response |
±5%
for 100% load variation; Recovery in 2 to 3 cycles. |
| Load Power
Factor |
Unity
to 0.8 lag within maximum specified output power limits. |
| Short-term
Overload |
110%
for 30 mins; 150% for 10 secs.; 200% for 5 cycles. |
| General |
Protections |
Mains
Over/Under Voltage, Output O/U Voltage, DC O/U Voltage,
Output Overload, Overheat, Built-in soft-start, Snubber for Devices. |
| LED
Indications |
Mains
On, DC On, Output On, Mains Over/Under Voltage.
Output O/U Voltage, DC O/U Voltage, Output Overload, Overheat. |
| Metering |
Analog meter to measure the AC Voltage & AC Current.
Digital meter to measure the Frequency. |
| Isolation |
The
FC Output is isolated from the Mains Input. |
| Protection
Class |
IP21. |
| Finish |
DA
Gray IS632. |
| Weight (in
Kgs.) |
68 |
77 |
88 |
114 |
Dimensions
(W x D x H) (mm) |
300
x 600 x 640 |
300
x 600 x 640 |
375
x 600 x 720 |
375
x 600 x 720 |
| Environment |
Temperature |
0°C
to 45°C (50°C peak). |
| Humidity |
0
to 95% non-condensing at 30°C. |
| Selection
Chart |
| Model |
Output |
| Frequency |
Voltage |
Power |
| 60Hz
Models |
| FC98-2/60 |
60Hz |
115
Volts |
2.0
KVA |
| FC98-3/60 |
60Hz |
115
Volts |
3.0
KVA |
| FC98-5/60 |
60Hz |
115
Volts |
5.0
KVA |
| FC98-7.5/60 |
60Hz |
115
Volts |
7.5
KVA |
| 400Hz
Models |
| FC98-2/400 |
400Hz |
115
Volts |
2.0
KVA |
| FC98-3/400 |
400Hz |
115
Volts |
3.0
KVA |
| FC98-5/400 |
400Hz |
115
Volts |
5.0
KVA |
| FC98-7.5/400 |
400Hz |
115
Volts |
7.5
KVA |
| *
All above models are available with battery back-up on request. |
|
|