| Features |
|
 |
- Filters Power
Line Noise, Spikes and Transients
- Isolates
Sensitive Equipment from Noisy Power Lines
- Complete
Electrostatic Shielding
- Minimizing
Common Mode Noise by Over 110dB, Which is Impossible with Conventional
Ordinary Isolation Transformers
- Minimises
Transverse Mode Noise
|
|
| Applications |
| 1. |
In
computer the presence of spikes, transients or noise in the supply
line will lead to erratic behavior of the computer. Crotechs
ISOLINE eliminates line disturbances and prevents faulty and erratic
operations. |
| 2. |
In
Instrumentation and telemetry, line disturbances will lead to faulty
recordings or readings. Crotechs ISOLINE completely isolates
power line disturbances and ensures more reliable operation of the
equipment. |
| 3. |
For
patients safety in hospitals, all diagnostics or therapeutic
medical equipment should be completely isolated from the supply
line. Complete patient/operator safety is assured by ISOLINE due
to its excellent DC isolation as well as total electrostatic shielding
from the power line. |
| 4. |
Other
systems essentially requiring ISOLINE are digital communication
systems, audio and video recording equipment, which get badly affected
by line noise. |
| ISOLINE
Ultra Isolation Transformers are available from 2500VA to 25KVA,
Single phase as standard models. For three phase input, Three single
phase units can be connected in STAR or DELTA configuration. They
are conservatively rated to ensure long life and highest reliability.
|
| Description |
Ordinary
isolation transformers isolate one circuit from another, while magnetically
coupling wanted energy from one to other. Such a transformer is
adequate for use with low gain circuits or insensitive instruments.
However, if the transformers must work into a high gain load or
sensitive instrumentation, noise potentials between the primary
circuit and ground must be prevented from affecting the secondary
circuits due to capacitive and resistive coupling between the transformers
windings. |
| Traditional
techniques for keeping noise from reaching the transformer secondary
e.g. the standard faraday shield (A grounded single turn of conducting
foil between the windings) will divert much of the primary noise
current to ground. But noise still can be coupled into the secondary
because of the electrostatic field around the faraday shield and
will cause serious problems in the secondary circuits. |
| To
overcome this problem, ISOLINE range employs a unique multiple shielding
technique that reduces the interwinding capacitance below 0.009pF
and increases the DC isolation over 100M ohms. ISOLINE has therefore
only ten thousandth the noise leakage of an ordinary transformer. |
| Technical
Specifications |
| Input
Voltage |
115/230V
nominal. Two windings in parallel or series (2.5KVA & 5KVA)
230V nominal (7.5KVA and above). Other voltages on request. |
| Acceptable
Input Range |
±10%. |
| Output Voltage |
230V AC. |
| Mode of Operation |
1:1 Isolation
transformer. |
Common Mode
Noise Rejection
(Transients, Spikes and Surges) |
Over
110dB. |
| Coupling Capacitance |
Less than 0.009pF. |
| DC Galvanic
Isolation |
Over 100Mohms
between any windings or windings to ground. |
| Breakdown
Strength |
2500V AC for
2 minutes acceptable. |
| Line Frequency |
47 to 63Hz. |
| Load Regulation |
±3%. |
| Termination |
On terminal block/Brass
studs of adequate rating. |
| Power
Rating |
| MODEL |
POWER
RATING
KVA |
DIMENSIONS
*
W x H x D (mm) |
WEIGHT
(approx.) Kg. |
| 9815 |
2.5 |
250
x 320 x 240 |
40 |
| 9816 |
5.0 |
250
x 390 x 240 |
55 |
| 9817 |
7.5 |
370
x 450 x 285 |
94 |
| 9818 |
10.0 |
370
x 490 x 285 |
122 |
| 9819 |
15.0 |
370
x 535 x 285 |
152 |
| 9820 |
20.0 |
370
x 680 x 285 |
225 |
| 9821 |
25.0 |
425
x 600 x 340 |
225 |
| All
dimensions include leg height. |
| * Higher Capacity
Systems on Request. |
|
|