| Technical
Specifications |
| VERTICAL
DEFLECTION |
| Deflection
Coefficient (CH1 &CH2) |
1mV/div
to 20V/div.
5mV/div to 20V/div in 12 calibrated steps in 1-2-5 sequence.
x5 Magnification increases the sensitivity to 1mV/div & 2mV/div
(LED indicated). |
| Accuracy |
±3%. |
| Bandwidth |
DC
- 30MHz (-3dB), dc coupled.
10Hz - 30MHz (-3dB), ac coupled. |
| Rise
Time |
11.6ns
or less. |
| Display
Modes |
CH1
only, CH1 & CH2 alternate or chop mode, Algebraic addition CH1+CH2,
Algebraic subtraction CH1-CH2, CH2 invert & X-Y. |
| Input
Impedance |
1M
ohms // 25pF (approx). |
| Maximum
Input Voltage |
400V
(DC + AC peak). |
| Internal
Trigger Signal |
CH1
or CH2 signal. |
| TIME
BASE |
| Sweep
Speed |
18
calibrated steps. 0.5µs/div to 0.2s/div in 1, 2 & 5 sequence. |
| Sweep
Magnifier |
x5
Magnification. |
| Accuracy |
±3%. |
| Variable |
Uncalibrated
continuously variable control between steps, extends fastest sweep
speed to 40ns/div (approx) (Uncal LED indication). |
| Hold-off
Time |
4:1
variable control. |
| TRIGGER
SYSTEM |
| Triggering
Mode |
Automatic
or Normal with Level Control. |
| Source |
CH1
/ CH2 / LINE / EXT. |
| Slope |
Positive
or Negative. |
| Coupling |
ac
/ dc / HF reject or TV Frame / TV Line. |
| Trigger
Sensitivity |
Internal
: AUTO 1 div 30Hz - 30MHz
NORM 1 div 3Hz - 30MHz.
External : AUTO 1V p-p 30Hz - 30MHz
NORM 1V p-p 3Hz - 30MHz
(Typical 40MHz at 2 div). |
| HORIZONTAL
DEFLECTION |
| Deflection
Coefficient |
Same
as CH2. |
| Bandwidth |
DC
- 1MHz (-3dB). |
| Input
Impedance |
1M
ohms and 25pF (approx). |
| COMPONENT
TESTER/ COMPARATOR |
Dual
Component Tester allows comparison of a Device-Under-Test (D.U.T.)
and a sample device. |
| Test
Voltage |
8.6V
rms, 50-60Hz. |
| Test
Current |
28mA
max. |
| TRIPLE
OUTPUT D.C. SOURCE |
Three
independent, regulated DC outputs, +5V at 1A max and ±12V
at 200mA max. continuous (common floating w.r.t. ground). |
| Line
/ Load Regulation |
±2%. |
| GENERAL
INFORMATION |
| Cathode
Ray Tube |
140mm
Rectangular Screen, Internal Graticule, 8 x 10 cm, P31 phosphor.
Accelerating potential : 2kV. |
| Z
Modulation |
30V
p-p signal upto 1MHz modulates at normal intensity. |
| Calibrator |
Provides
0.2V ±2%, 1KHz squarewave output for probe compensation. |
| Power
Requirement |
115V/230V
AC ±10%, 47/65Hz, 40VA (max.). |
| Dimensions |
165
(H) x 320 (W) x 420 (D) mm approx. |
| Weight |
8
Kgs. approx. |
| Accessories |
Instruction
Manual, 2 Input BNC Leads, Component Tester Leads.
Optional : High impedance switch probe with x1 or x10 Attenuation
(Model 306), Trolley. |