| Technical
Specifications |
| VERTICAL
DEFLECTION |
| Deflection
Coefficient (CH1 & CH2) |
1mV/div
to 20V/div.
5mV/div to 20V/div in 12 calibrated steps in 1-2-5 sequence.
x5 Magnification increases the sensitivity to 1mV/div & 2mV/div
(LEDindicated). |
| Accuracy |
±3%. |
| Bandwidth |
DC
- 30MHz (-3dB), dc coupled
10Hz - 30MHz (-3dB), ac coupled. |
| Rise
Time |
11.6ns
or less. |
| Display
Modes |
CH1
only, CH1 & CH2 alternate or chop mode, Algebraic addition CH1+CH2,
Algebraic subtraction CH1-CH2, CH2 invert & X-Y. |
| Input
Impedance |
1M
ohms // 25pF (approx). |
| Maximum
Input Voltage |
400V
(DC + AC peak). |
| Internal
Trigger Signal |
CH1
or CH2 signal. |
| TIME
BASE |
| Sweep
Speed |
18
calibrated steps. 0.5µs/div to 0.2s/div in 1, 2 & 5 sequence. |
| Sweep
Magnifier |
x5
Magnification extends the sweep speed to 100ns/div.
x5 Magnification indication wtih LED. |
| Accuracy |
±3%. |
| Variable |
Uncalibrated
continuously variable control between steps, extends fastest sweep
speed to 40ns/div (approx) (Uncal LED indication). |
| Hold-off
Time |
4:1
(approx.) variable control. |
| TRIGGER
SYSTEM |
| Triggering
Mode |
Automatic
or Normal with Level Control. |
| Source |
CH1
/ CH2 / LINE / EXT. |
| Slope |
Positive
or Negative. |
| Coupling |
ac
/ dc / HF reject or TV-V / TV-H. |
| Trigger
Sensitivity |
Internal
: AUTO 1 div 30Hz - 30MHz
NORM 1 div 3Hz - 30MHz.
External : AUTO 1V p-p 30Hz - 30MHz
NORM 1V p-p 3Hz - 30MHz
(Typical 40MHz at 2 div). |
| HORIZONTAL
DEFLECTION |
Horizontal
input via CH2 (CH1 operates as Y). |
| Deflection
Coefficient |
Same
as CH2. |
| Bandwidth |
DC
- 1MHz (-3dB). |
| Input
Impedance |
1M
ohms and 25pF (approx). |
| GENERAL |
| Cathode
Ray Tube |
140mm
Rectangular Screen, Internal Graticule 8 x 10 cm, P31 Phosphor.
Accelerating potential : 2kV. |
| Trace
Rotation |
Front
Panel Control, allows ±5º of trace adjustment. |
| Z
Modulation |
30V
p-p signal upto 1MHz modulates at normal intensity. |
| Calibrator |
Provides
0.2V ±2%, 1KHz squarewave output for probe compensation. |
| DUAL
COMPONENT TESTER/COMPARATOR |
Dual
Component Tester allows comparison of a Device-Under-Test (D.U.T.)
and a sample device. |
| Test
Voltage |
8.6V
rms. |
| Test
Current |
28mA
max. |
| Test
Frequency |
50Hz
or 60Hz. |
| TRIPLE
OUTPUT D.C. SOURCE |
Three
independent, regulated DC outputs, +5V at 1A max and ±12V
at 200mA max. continuous (common floating w.r.t. ground). |
| Line
/ Load Regulation |
±2%. |
| Ripple |
Less
than 8mV r.m.s. |
| Termination |
2mm
Jacks on the Front Panel. |
| 0.02Hz
- 2MHz FUNCTION GENERATOR |
| Frequency
Range |
0.02Hz
to 2MHz in 8 decade ranges. |
| Output
Waveform |
DC,
sine, triangle, square. |
| DC
Offset |
±5V
(across 50 ohms), ±10V (open circuit). |
| Maximum
Output Voltage |
10V
p-p for all functions (with 50 ohms loads).
20V p-p open circuit (DC + AC peak not exceed 10V across 50 ohms).
|
| Output
Impedance |
50
ohms (nominal). |
| Attenuator |
0dB
to 40dB in steps of 20dB, 20dB fine attenuation by amplitude control. |
| Accuracy |
±0.5dB
per 20dB step at 1KHz. |
| Sine
Distortion |
Less
than 3% upto 200KHz. |
| 100MHz
DIGITAL FREQUENCY COUNTER |
| Frequency
Range |
10Hz
to 100MHz (usable). |
| Gate
Time |
0.01,
0.1, 1 & 10 sec (switch selectable). |
| Accuracy |
±1
count ± Time Base accuracy. |
| Time
Base |
10MHz
crystal oscillator. |
| Accuracy |
±20
ppm at 25ºC. |
| Stability |
±30
ppm over 0ºC to 50ºC range. |
| Inputs |
(Switch
Selectable). |
| Gen |
Frequency
of Function Generator. |
| Scope |
Signal
through triggered channel of scope. |
| Ext |
External
signal through BNC connector. |
| Sensitivity |
|
| Scope
Input |
Min.
4 div p-p swing on oscilloscope. |
| Ext
Input |
20mV
rms over 10Hz to 50MHz.
50mV rms over 50MHz to 100MHz.
5V p-p max. |
| Input
Impedance |
|
| Ext
Input |
1M
ohm // 30pF. |
| Display |
7
digit, 0.3" LED display indicates frequency in Hz, KHz &
MHz. |
| GENERAL
INFORMATION |
| Power
Requirement |
115V/230V
AC ±10%, 47/65Hz, 75VA (max.). |
| Dimensions |
235
(H) x 315 (W) x 420 (D) mm approx. |
| Weight |
10
Kgs. approx. |
| Accessories |
Instruction
Manual, 2 Input BNC Leads, Component Tester Leads.
Optional : High impedance switch probe with x1 or x10 Attenuation
(Model 306), Trolley (Model 304). |