| Technical
Specifications |
| VERTICAL
DEFLECTION (Y) |
| Deflection
Coefficient (CH1 & CH2) |
1mV/div
to 5V/div. 5mV/div to 5V/div in 10 calibrated steps in 1-2-5 sequence.
x5 Magnification increases the sensitivity to 1mV/div to 1V/div. |
| Accuracy |
x1
: ±3%, x5 : ±5%. |
| Variable |
1
/ 2.5 times uncalibrated continuously variable control extends the
Deflection Coefficient to more than 12.5V/div. |
| Bandwidth |
x1
: DC to 20MHz (-3dB), dc coupled.
10Hz to 20MHz (-3dB), ac coupled.
x5 : DC to 7MHz (dc coupled)
10Hz to 7MHz (ac coupled). |
| Rise
Time |
14ns
or less. |
| Display
Modes |
CH1,
CH2, DUAL (CH1, CH2 ALT/CHOP), Algebraic ADD and SUBTRACT, CH2 INVT
& X-Y (CH1 as X, CH2 as Y). |
| Input
Impedance |
1M
ohms // 25pF approx. |
| Maximum
Input Voltage |
300
Volts (dc + peak ac). |
| Internal
Trigger Signal |
CH1,
CH2 or Alternate. |
| CH1
SIG OUT |
| Output
Voltage |
Minimum
20mV for 1 div of CH1 input signal. |
| Output
Impedance |
50
ohms (approx.). |
| Bandwidth |
50Hz
to 5MHz. |
| TIME
BASE |
| Sweep
Speed |
20
Calibrated steps. 0.1µs/div to 0.2s/div in 1, 2 & 5 sequence. |
| Sweep
Magnifier |
x5
Magnification increases the fastest sweep upto 20ns/div. |
| Accuracy |
±3%. |
| Variable |
Uncalibrated
continuously variable control between steps, extends slowest sweep
speed to 0.5s/div (approx.). |
| ALT
MAG Trace |
x5
magnified sweep is displayed along with normal sweep. |
| TRIGGER
SYSTEM |
| Triggering
Mode |
AUTO,
NORM, TV-V, TV-H. |
| Source |
INT
(CH1 or CH2) / CH2 / LINE / EXT. |
| Slope |
Positive
or Negative. |
| Coupling |
ac
coupling. |
| Trigger
Sensitivity |
|
| Internal |
Auto
: 1.5 div - 20Hz to 25MHz.
Normal : 1.5 div - 10Hz to 25MHz.
Lock : 2.0 div - 50Hz to 20MHz.
Alt : >3div - 50Hz to 25MHz. |
| External |
Auto
0.3V p-p - 20Hz to 20MHz.
Normal 0.3V p-p - 10Hz to 20MHz.
Lock 0.3V - 50Hz to 20MHz. |
| HORIZONTAL
DEFLECTION |
| Deflection
Coefficient |
Same
as CH1. |
| Bandwidth |
DC
- 1MHz (-3dB). |
| Input
Impedance |
1M
ohms & 25pF approx. |
| Phase
Difference |
<3º
(DC - 50KHz). |
| COMPONENT
TESTER |
Component
Tester allows V.I. Characteristics of a Device Under Test (D.U.T.). |
| Test
Voltage |
9V
rms (No Load). |
| Test
Current |
2mA
when shorted. |
| GENERAL
INFORMATION |
| Cathode
Ray Tube |
140mm
Rectangular screen, Internal Graticule, 8 x 10 cm, P31 phosphor.
Accelerating potential : 2kV. |
| Z-Modulation |
±5V
p-p signal upto 2MHz modulates at normal intensity. |
| Calibrator |
Provides
0.5V ±2%, 1KHz ±2% square-wave output for probe compensation. |
| Power
Requirement |
220V
AC ±10%, 50Hz ±5%, 35VA (max.). |
| Dimensions |
140
(H) x 335 (W) x 375 (D) mm approx. |
| Weight |
7.2
Kgs. approx. |
| Accessories |
Instruction
Manual, 2 High impedance switch probe with x1 or x10 attenuation,
Mains Cord. |
| Environmental
Specifications |
Operating
conditions.
Normal : 10ºC to 35ºC, RH 45% to 85%.
Operational : 0ºC to 40ºC, RH 35% to 90%. |