3MHz AC Millivoltmeter   Model 5002
 
     
 
Features
Model 5002
  • High Sensitivity 1mV FSD
  • Wide Frequency Range 20Hz to 3MHz
  • High Input Impedance
  • dB Scale Calibration Covering -60 to +50dB in 10dB Steps
  • Wide Voltage Range from 1mV to 300V Full Scale in 12 Ranges
  • Internal Calibration Signal Provision
  • The Built-in Amplifier can be used seperately
  • Protected against Overloads

Technical Specifications
Voltage Ranges 1mV to 300V full scale in twelve ranges in 1-3-10 sequence.
Bandwidth 20Hz to 3MHz.
dB Ranges -60dB to +50dB in 10dB steps.
Input Impedance 10M ohms // 40pF nominal.
Calibration Reads rms value of sinewave, voltage indication proportional to average value of applied signal, linear voltage scales 0 to 3, 0 to 10, dB scale -20 to +2dB (0dBm = 1mW in 600 ohms).
Accuracy 1mV to 30mV ranges :
±3% of FSD 30Hz - 1MHz
±5% of FSD 20Hz - 3MHz.
100mV to 3V ranges :
±5% of FSD 30Hz - 500KHz
±10% of FSD 20Hz - 3MHz.
10V & above ranges :
±5% of FSD upto 100KHz.
Calibration Signal Built-in 1V CAL signal available on panel.
Accuracy : ±1% at 230V.
Characteristics as an Amplifier Gain Approx. 40dB on 1mV range.
Frequency Range Useful gain from 10Hz to 150KHz between ±1dB.
Distortion <5%.
Output Impedance 2.2K ohms approx.
Power 115/230V AC ±10%, 47-65Hz, 5VA (max.).
Dimensions 140 (H) x 210 (W) x 230 (D) mm.
Weight 2.5 Kgs. approx.
 