| Features |
|
- Wide Frequency
Range from 0.2Hz to 2MHz
- Sine,
Triangle, Square, Pulse, Ramp, TTL & Sweep Output
- Variable
Time Symmetry for Pulse & Ramp Waveform
- Variable
DC Offset Control
|
- 20dB x
2 Attenuator
- Output
Overload Protection
- VCF Input
- LOG \
LIN Sweep Mode
|
| Technical
Specifications |
| Frequency
Characteristics |
|
| Range |
0.2Hz to 2MHz. |
| Dial Accuracy |
±5%. |
| Waveform
Characteristics |
|
| Output Waveforms |
Sine, Triangle,
Square, Pulse, Ramp, TTL. |
| Symmetry /
Duty Cycle |
10% to 90%
Cont. variable for asymmetric waveforms like Pulse & Ramp (
Upto 200KHz only). |
| Sinewave Distortion |
<1% from
20Hz to 200KHz. |
| Triangle Linearity |
98% upto 100KHz,
95% above 100KHz. |
| Square Rise
/ Fall Time |
<100ns. |
| Output
Characteristics |
|
| Amplitude |
20Vp-p (Open
Circuit), 10Vp-p (into 50 Ohm Load). |
| Attenuator |
20 ±1dB.x
2, 20dB cont. variable. |
| Output DC Offset |
±10V
open circuit, ±5V into 50 Ohm load (dc ± ac peak). |
| Output Impedance |
50 Ohms ±5%. |
| Protection |
Short circuit
protected. |
| TTL
Output |
|
| Rise/Fall Time |
<25ns. |
| Level |
Standard TTL. |
| VCF
Characteristics |
|
| VCF Input |
0 to 10V for
Full Range. |
| VCF Input Impedance |
10K Ohm, ±10%. |
| Sweep
Characteristics |
|
| Sweep Mode |
Internal /
External. |
| Sweep Type |
Linear, Log. |
| Sweep Time |
0.5s to 30s
Variable. |
| Sweep Width |
100 : 1 Variable. |
| Power
Source |
115V / 230V
±10%, 50 / 60 Hz AC. |
|
|